TEKNOSAFE FLAME GUARD 2467-10

Intumescent primer and paint

  • Water-borne
  • Paint
  • Primer

TEKNOSAFE FLAME GUARD 2467-10 is a water-borne intumescent primer and paint for interior solid wood panelling and cladding, and wood-based panels. Substrate: Solid wood or wood-based panels with thickness > 8 mm and density ≥ 338 kg/m³ when taken in conjunction with the relevant fire classification report.

Used as an industrial primer or paint as part of a system called Teknos FR Panel with TEKNOSAFE FLAME PROTECT 2468-00 to improve “reaction to fire” (EN 13501-1) of interior wooden surfaces - see https://www.teknos.com/products/teknosafe-flame-guard-2467-10/. Before using the product, Teknos should be contacted to check the suitability of the product for the object in question. Fire-retardant performance has been classified according to B-s1, d0 EN 13501-1 (SBI test). Durability classes of reaction to fire performance, of fire-retardant wood-based product in end use applications according to EN 16755 - DRF class INT1 and INT2. M1 classification, A+ Émissions l'air intérieur: When used in an industrial setting.

Surface preparation

The wood must be free from wood dust and contamination. The moisture content of the wood should be approx. 10% and should not exceed 12%.

Application conditions

The temperature of the air, the surface and the paint shall be above +10°C and the relative humidity of the air below 80% during the time of application and drying. The best result is achieved when the temperature of the air is between +23°C and +38°C, the relative humidity of the air is 50-70% and the ventilation good. Stir the paint thoroughly before use, preferably using mechanical stirring. It is recommended to overcoat TEKNOSAFE FLAME GUARD 2467-10 with e.g., TEKNOSAFE FLAME PROTECT 2468-00 in cases where the surfaces concerned must be washable, or where a certain haptic is expected (e.g., wooden walls or frequently cleaned ceiling or panels). After on-site cutting the specified loading rate must be re-instated. For all coated solid wood or wood-based panels, a non-marking protective layer of minimum 1.5 mm thickness (e.g., polyethylene film) is recommended to be used between coated surfaces.

Storage

Must not freeze. The best storage temperature is +10°C - +25°C.

Apply industrially.
Volatile organic compound (VOC) abt. 0 g/l
Gloss Matt
Tinting system Teknocolor
Theoretical spreading rate The core classification is made with ≥250 g/m² TEKNOSAFE FLAME GUARD 2467-10 with or without ≤100 g/m² TEKNOSAFE FLAME PROTECT 2468-00 or in conjunction with additional relevant fire classification reports.
Drying time – touch dry 20-30 min.
Thinner Water.
Clean up Water.
Colours Clear and Base T (all colours). Base colour may vary slightly. After tinting, colour control is highly recommended. All tinting recipes are developed by Teknos Shade service.
Packages Available in a range of standard pack sizes.
Safety markings See safety data sheet.
Approvals & certificates M1 classification,A+ Émissions l'air intérieur