HYDROPUR 2K COLOR 7515-30

Water-soluble 2C top coat for interior use

Surface preparation

Every substrate must be well-cleaned, dry and free from grease and oil. Coating removal: Sand, strip

Application

Stir or shake the product well for several minutes before use, if necessary by machine.

Application conditions

Recommended temperature for surroundings and product: +15°C-25°C. Do not apply below +10°C.

Storage

Storage temperature is +5°C - +30°C.

Note: When applying a white or pastel-coloured coating to surfaces subject to considerable wear we recommend overcoating with 2C clear coatings to improve ring resistance (metal wear). For exterior applications we recommend overcoating with HYDROPUR 2K 7590. After the last application of HYDROPUR 2K COLOR 7515, do not wait any longer than 72 hours before recoating with HYDROPUR 2K 7590. Intermediate sanding is otherwise necessary. Technical requirement: Adhesive strength according to DIN EN ISO 2409; Gt 0
Volatile organic compound (VOC) abt. 39 g/l
Pot life 1 h (+23 °C)
Mixing ratio 10:1 by volume (comp. A : comp. B)
Hardener Comp. B: HYDROPUR 7515-99
Gloss Semi-matt
Tinting system Largo;Teknocolor
Theoretical spreading rate 100-200 g/m²; 6.6 m²/kg
Density abt. 1.21 g/ml
Drying time – dust free after 60 minutes
Drying time – touch dry after 90 minutes
Drying time – through-dry after 24 hours
Clean up Wash the equipment immediately after use. Water, ACETON 8000-98.
Colours Available in all RAL and NCS-S colours or at your request.
Safety markings See safety data sheet.
Gloss value 30