TEKNOFLOOR 500F
Epoxy coating
- 2-component
- Topcoat
TEKNOFLOOR 500F is a solvent-free two-pack epoxy coating for concrete floors. The product can be used on the floors of food production spaces (Smithers Rapra, Certificate Number GC0070).
Used on all industrial floors where a level, conformal coating with a good mechanical resistance is required. The coating withstands water, chemicals, oil, grease and petrol. It does not resist strong acids nor continuous attacks by organic acids or strong solvents. The abrasion resistance of the coating is very good. When good colour and gloss retention is required TEKNOFLOOR 500F can be overcoated with polyurethane top coats of the TEKNODUR 0100 series. The coating becomes level by itself on even surfaces.
Technical data sheet
Safety data sheet
Other product specific documents
Surface preparation
NEW CONCRETE SURFACES: The concrete must be at least 4 weeks old and well-hardened so that all moisture from casting is bound and the surface dry. The moisture of the concrete must not exceed 97% as relative humidity or 4% by weight (by 54 / BLY 12).
Dense laitance is to be removed from steel-trowelled concrete by shot-blasting or surface grinding. Brittle and powdery top layers are treated so that the solid concrete containing aggregate is exposed. Thereafter all cement dust is removed by vacuum cleaner or brush. The concrete surface must be clean of anything that might hinder the adhesion.
OLD CONCRETE SURFACES: Uncoated, greasy floors are cleaned by emulsion wash. Thereafter laitance is removed by shot-blasting, scarifying, surface grinding or etching. Scarifying and shot-blasting are the best methods for removal of disrepair concrete or old flaking paint or composition layers.
The surface preparation method for both new and old concrete is chosen according to condition of the concrete and strain the floor will be exposed to. The best method for floors to be attacked by heavy abrasion, chemicals or hot water is scarifying or shot-blasting. Surface grinding is enough if the floor will be subjected to minor abrasion only. In general, surface preparation by etching is not recommended for composition floors within industry. Etching is mainly used for small areas when mechanical preparation methods are not applicable.
Etching is to be done with RENSA ETCHING etching liquid. Rinse the floor with water after etching and allow to dry.
All special jobs should be done before the application of the actual priming. E.g. cutting grooves at joints between steel and concrete. Cutting working and expansion joints open. Fitting up skirting and rounding of corners. Filling cavities and cervices, and possible levelling down the floor. Filling can be done with TEKNOPOX FILL or with stiff putty prepared by adding an adequate amount of dry sand (e.g. 0.1 - 0.6 mm) to undiluted varnish.
Application
MIXING OF THE COMPONENTS: Before application the base and hardener are mixed in right proportion. Stir thoroughly down to the bottom of the vessel. Mixing by machine is recommended, for example a slow-rotating hand-drill equipped with a mixer. Inadequate stirring or incorrect mixing ratio results in imperfect curing and impaired film properties.
The application is done within 6 - 24 hours of priming depending on the temperature. The recommended coat thickness is achieved by a suitable indentation of the steel trowel. Smooth down with a short-haired mohair roller.
Applying films above 1.0 mm, while the mixer is rotating add slowly quartz sand or natural sand (see table) into the mixture. Carry on mixing until the component is homogeneous.
Spread the composition with an adjustable trowel, the slit of which can be adjusted to give the coat thickness required. Smooth the coat with a mohair roller and use a plastic porcupine roller to delete air bubbles.
It is recommended that paint of the same batch is used for painting large uniform floors. If paint from different batches must be used, the application is to be planned so that the seams between batches are done to natural lines, i.e. sills and expansion joints.
Application conditions
The surface to be treated must be dry. During the application and drying period the temperature of the ambient air, the surface and the product shall be above +10°C and the relative air humidity below 80%. Additionally, the temperature of the surface to be treated and the product must be at least +3°C above the dew point of the ambient air.
Storage
The storage stability is shown on the label. Must be stored tightly closed and kept cool.
Solids | abt. 100 % by volume |
---|---|
Total mass of solids | abt. 1200 g/l |
Volatile organic compound (VOC) | abt. 0 g/l |
Pot life | 10 min. (+23 °C) |
Pot life, +23°C | 30 - 60 min (mixture poured out on the floor) 10 - 15 min (mixture kept in the vessel) |
Mixing ratio | 10:3 by volume (comp. A : comp. B) |
Hardener | Comp. B: TEKNOFLOOR HARDENER 500H |
Gloss | Full gloss |
Tinting system | Teknomix |
Practical spreading rate | Coating: 0.3 - 0.5 l mixture/m² depending on film thickness. Composition: 2 l ready composition/m² depending on the film thickness. |
Drying time – dust free | 6 h (ISO 9117-3:2010) |
Drying time – touch dry | 16 h (ISO 9117-5:2012) |
Drying time – fully cured | 7 d |
Thinner | Not to be diluted. |
Clean up | TEKNOSOLV 9506. Wash the equipment immediately after use. |
Colours | Base 1 and base 3 (white and opaque colours). Also certain colours of the RAL Colour Card by factory delivery. NOTE! Sunlight will change the colour and glossiness of the coating in the course of time. |
Safety markings | See safety data sheet. |
Approvals & certificates | CE marking,M1 classification,Smithers Rapra |