TEKNOFLOOR 300F

Epoxy varnish

  • Topcoat

TEKNOFLOOR 300F is a solvent-free, two-pack epoxy varnish for concrete floors.

Use: For priming under epoxy coatings and flooring compositions and colour sand mortars. When filled with sand, the varnish can be used for repairing of concrete floors and rounding off the corners. TEKNOFLOOR 300F is resistant to abrasion and chemicals. Diluted varnish penetrates into the pores of the concrete so sealing the surface and ensuring good adhesion to the substrate. NOTE! The colour of the varnish may change on objects exposed to sunlight. The product has CE approval for protection of concrete structures. TEKNOFLOOR 300F is suitable for use in food preparation and packaging environments (Smithers Rapra, Certificate Number GC0071).

Surface preparation

NEW CONCRETE SURFACES: The concrete must be at least 4 weeks old and well-hardened so that all moisture from casting is bound and the surface dry. The moisture of the concrete must not exceed 97% as relative humidity or 4% by weight (by 54 / BLY 12). Dense laitance is to be removed from steel-trowelled concrete by shot-blasting or surface grinding. Brittle and powdery top layers are treated so that the solid concrete containing aggregate is exposed. Thereafter all cement dust is removed by vacuum cleaner or brush. The concrete surface must be clean of anything that might hinder the adhesion. OLD CONCRETE SURFACES: Uncoated, greasy floors are cleaned by emulsion wash. Thereafter laitance is removed by shot-blasting, scarifying, surface grinding or etching. Scarifying and shot-blasting are the best methods for removal of disrepair concrete or old flaking paint or composition layers. The surface preparation method for both new and old concrete is chosen according to condition of the concrete and strain the floor will be exposed to. The best method for floors to be attacked by heavy abrasion, chemicals or hot water is scarifying or shot-blasting. Surface grinding is enough if the floor will be subjected to minor abrasion only. In general, surface preparation by etching is not recommended for composition floors within industry. Etching is mainly used for small areas when mechanical preparation methods are not applicable. Etching is to be done with RENSA ETCHING etching liquid. Rinse the floor with water after etching and allow to dry. All special jobs should be done before the application of the actual priming. E.g. cutting grooves at joints between steel and concrete. Cutting working and expansion joints open. Fitting up skirting and rounding of corners. Filling cavities and cervices, and possible levelling down the floor. Filling can be done with TEKNOPOX FILL or with stiff putty prepared by adding an adequate amount of dry sand (e.g. 0.1 - 0.6 mm) to undiluted varnish. Additional instructive information for surface preparation can be found in standards EN ISO 12944-4 and ISO 8501-2.

Application

The priming coating: The priming coat is applied "wet-to-wet" with varnish diluted 30 - 50% with TEKNOSOLV 9506 or TEKNOSOLV 9515. The amount of thinner depends on the density of the concrete. Pour the mixture on the floor immediately after mixing as a streak. Apply e.g. with a short-piled roller, generously so that the surface is sealed. Recoat immediately all areas that have absorbed the varnish completely. The number of priming coats depend on the quality of the concrete's surface. The priming coating may have to be done several times. If the surface remains porous, air bubbles may form when the coating is applied, and this will cause craters on the surface. The coating can be applied when the priming coat has dried for at least 6 hours. Avoid intervals longer than 24 hours. If the priming coat has been applied more than 24 h ago the surface must be rubbed down and cleaned before it is overcoated. The top coating: The top coat is applied with varnish diluted 30 - 50% with TEKNOSOLV 9506 or TEKNOSOLV 9515. Pour the mixture on the floor immediately after mixing as a streak and apply e.g. with short-piled roller. If necessary, the top coating can be redone after 6 – 24 h from the first application.

Application conditions

During the application and drying period the temperature of the ambient air, the surface and the product shall be above +10°C and the relative air humidity below 80%. Additionally, the temperature of the surface to be treated and the product must be at least +3°C above the dew point of the ambient air.

Storage

The storage stability is shown on the label. Store in a cool place and in tightly closed containers.
Total mass of solids abt. 1100 g/l
Volatile organic compound (VOC) abt. 0 g/l
Pot life 10 min. (+23 °C)
Pot life, +23°C +23°C Undiluted mixture: 30 - 40 min (poured out on the floor) 10 min (kept in the vessel) Diluted mixture: 40 - 60 min (poured out on the floor)
Mixing ratio 2:1 by volume (comp. A : comp. B)
Hardener Comp. B: TEKNOFLOOR HARDENER 300H
Gloss Full gloss
Practical spreading rate Depending on the roughness and absorbency of the surface. Standard value for a steel-trowelled concrete floor: for priming 3 - 6 m²/l.
Drying time – fit for light traffic 16 h
Thinner TEKNOSOLV 9506, TEKNOSOLV 9515.
Clean up TEKNOSOLV 9506 or TEKNOSOLV 9515.
Safety markings See safety data sheet.
Approvals & certificates CE marking,Smithers Rapra